Key Architecture Highlights
- Chassis form factor: Tower (can be installed in a rack with the available Rack Mount Kit)
- Chipset: Intel Rocket Lake PCH-S, C266
- Cooling system: Supports ASHRAE A2 environments. Three fans. Two fixed system fans (front drive bay and rear). Additional fan attached to the processor heat sink and in the power supplies.
Applications
- Enterprise computing
- Virtualization and cloud computing
- Data center
Engineering Parameters
| Chassis form factor | Tower (can be installed in a rack with the available Rack Mount Kit) |
|---|---|
| Supported processors | One Intel processor. Choose from: * Intel Xeon 6300 Series processors up to to 8 cores, with core speeds up to 3.6 GHz * Intel Xeon E-2400 Series processors ("Raptor Lake-E") up to to 8 cores, with core speeds up to 3.5 GHz * Intel Pentium G7400 and G7400T processors ("Alder Lake-R") with 2 cores and core speeds up to 3.7 GHz |
| Chipset | Intel Rocket Lake PCH-S, C266 |
| Memory support | Memory support: Four DIMM sockets supporting Lenovo TruDDR5 DIMMs at 4400 MHz (Xeon processors) or 4400 MHz (Pentium processors). Support ECC UDIMMs. maximum memory: Up to 128 GB using 4x 32 GB UDIMMs. memory protection: Error-correcting code (ECC) |
| Drive bays | Available configurations: * 1x 2.5-inch NHS SATA SSD drive bays * 3x 3.5-inch NHS SATA HDD/SSD drive bays * 1x slim SATA ODD bay (optional) In addition, the ST50 V3 supports two M.2 drives installed in an M.2 adapter which is installed in PCIe slot 3. Note: Drive Bay 3 (3rd 3.5”) kit and M.2 2-Bay Enablement Kit are mutually exclusive because both kits are installed/assembled at PCIe Slot 3. |
| Maximum Internal Storage | * 2.5-inch drives: * 3.84TB using 1x 3.84TB Read Intensive SATA 6Gb NHS SSD * 3.5-inch drives: * 24TB using 3x 8TB 7.2K SATA 6Gb Non-Hot Swap 512e HDDs * Intermix of traditional HDDs and SSDs in the same array is not supported. |
| Network interfaces | Two integrated Gigabit Ethernet 1000BASE-T ports (RJ-45) based on Broadcom BCM5720 embedded controller, one can be shared with XCC for systems management. Third dedicated Gigabit Ethernet port for XCC systems management. |
| PCIe Expansion slots | Three PCIe slots (1x PCIe 5.0, 2x PCIe 4.0) as follows: * Slot 1: PCIe G4 x4 (x4 slot, open-ended) 25W full-height half-length (FHHL) * Slot 2: PCIe G5 x16 (x16 slot, closed-ended) 75W full-height half-length (FHHL) * Slot 3: PCIe G4 x4 (x4 slot, open-ended) 25W full-height half-length (FHHL) |
| Cooling system | Supports ASHRAE A2 environments. Three fans. Two fixed system fans (front drive bay and rear). Additional fan attached to the processor heat sink and in the power supplies. |
Warranty
Public manufacturer information does not specify the warranty term applicable to our supply channel. The supply region, channel and actual warranty service are confirmed in the supply contract.
Manufacturer information
Manufacturer informationVerified Documentation & Datasheets
Manufacturer product information
Download Document