
Key Architecture Highlights
- Chassis form factor: Controller enclosure: 2U rack mount Expansion enclosure: * DE240S: 2U rack mount
- Controller Configuration: Dual active-active controller configuration with automatic load balancing.
- Memory And Cache: 64 GB or 256 GB per system (32 GB or 128 GB per controller). Cache mirroring between the controllers. Flash-backed cache protection (includes battery for destaging to flash).
Applications
- Enterprise data storage
- Virtualized storage
- Business data protection
Engineering Parameters
| Chassis form factor | Controller enclosure: 2U rack mount Expansion enclosure: * DE240S: 2U rack mount |
|---|---|
| Controller Configuration | Dual active-active controller configuration with automatic load balancing. |
| RAID Level | RAID 0, 1, 3, 5, 6 and 10; Dynamic Disk Pools. * RAID 3 can be configured only through the Storage Manager Command Line (SMcli). * RAID 6, minimum six drives are required (five drives with one hot spare) for system functionality and data storage. |
| Memory And Cache | 64 GB or 256 GB per system (32 GB or 128 GB per controller). Cache mirroring between the controllers. Flash-backed cache protection (includes battery for destaging to flash). |
| Expansion The cabinet. Supports | * 4x DE240S (SAS SSD only) |
| Drive bays And Drive | * Up to 120 drives ( 24x NVMe drives in DE6600F controller enclosure + 96 SFF SSD hot-swap drive bays (4x DE240S SFF expansion enclosures). * DE240S SAS SSD only supported. |
| Backend Expansion Connection | * 8x 12 Gb SAS host ports (Mini-SAS HD, SFF-8644) (4 ports per controller) for expansion scale-up, daisy chaining of the expansion enclosures. * 2 x SAS expansion cards are required and must be installed in port1 only of the DE6600 enclosure controller. One in controller A, one in controller B. |
| Storage Capacity Supports | * Controller enclosure (367.2TB) + 4 x DE240S (1474.5TB) = 1841.5 TB * Scale up requires installation of a SAS expander card into slot 1 |
| Storage Agreements | SAN (Block access): FC, iSCSI, iSER/IB, NVMe/FC, NVMe/IB, NVMe/RoCE, and SRP/IB. |
| Host Interface | A controller enclosure has two controllers. Supported HICs are: * 8x 10/25 Gb iSCSI SFP28 host ports (DAC or SW fiber optics, LC) (4 ports per controller) * 8x 16/32 Gb FC SFP+ host ports (SW fiber optics, LC) (4 ports per controller) * 2x 40/100 Gb NVMe/RoCE QSFP28 host ports (DAC cable or SW fiber optics, MPO) (1 port per controller, supported in bay 2/ port 2 only) Note: The controllers no longer offers base ports. Host connectivity is provided with a pair of HICs. |
| Cooling | Controller enclosure: Five cooling fans per enclosure controller. DE600S expansion: Redundant cooling with two cooling modules DE120S, DE240S: Fans that are built into power supplies |
Warranty
Public manufacturer information does not specify the warranty term applicable to our supply channel. The supply region, channel and actual warranty service are confirmed in the supply contract.
Manufacturer information
Manufacturer informationVerified Documentation & Datasheets
Manufacturer product information
Download Document