
Key Architecture Highlights
- Cooling fans: • Up to 6 Standard (STD) fans, hot swappable.
- Chassis dimensions: • Height — 86.8 mm (3.41 inches) • Width — 481.6 mm (18.96 inches) • Depth — 907.74mm (35.74 inches)
- Chassis form factor: 2U rack server
Applications
- Corporate server computing
- Virtualization and cloud computing
Engineering Parameters
| Supported processors | Up to two 4th Generation Intel Xeon Scalable processors, with up to 32 cores per processor or Up to two 5th Generation Intel Xeon Scalable processors, with up to 28 cores per processor and optional Intel® QuickAssist Technology |
|---|---|
| Memory support | • 16 DDR5 DIMM slots, supports RDIMM 1.5 TB max, speeds up to 5600 MT/s • Supports registered ECC DDR5 DIMMs only Note: The maximum memory speed the system will support is 4800 MT/s due to the limitation of the processor. Note: 5600 MT/s RDIMMs are applicable for 5th Gen Intel Xeon Scalable Processors. |
| Storage controller | • Internal Controllers (RAID): PERC H755, PERC H965i, PERC H355 • Internal Controllers (non-RAID): HBA355i, HBA465i • Internal Boot: Boot Optimized Storage Subsystem (BOSS-N1): HWRAID 2 x M.2 NVMe SSD drives (hot swappable), or USB • External HBAs (non-RAID): HBA355e, HBA465e • External Controllers (RAID): H965e |
| Drive bays | Front bays: • Up to 12 x 3.5-inch SAS/SATA max 264 TB Mid bays: • Up to 12 x 3.5-inch SAS/SATA max 264 TB Rear bays: • Up to 4 x 3.5-inch SAS/SATA max 88 TB • Up to 4 x 2.5-inch NVMe with 3.5-inch carrier max 30.72 TB • Up to 2 x 2.5-inch NVMe max 15.36 TB • 4 x E3.S NVMe max 61.44 TB |
| Power supply specifications | • 1800 W Titanium 200—240 VAC or 240 VDC, hot swap redundant • 1400 W Platinum 100—240 VAC or 240 VDC, hot swap redundant • 1400 W Titanium 277 VAC or 336 VDC, hot swap redundant • 1400 W Titanium 100—240 VAC or 240 VDC, hot swap redundant • 1100 W Titanium 100—240 VAC or 240 VDC, hot swap redundant • 1100W LVDC –48 — –60 VDC, hot swap redundant • 700 W Titanium 200—240 VAC or 240 VDC, hot swap redundant |
| Cooling fans | • Up to 6 Standard (STD) fans, hot swappable. |
| Chassis dimensions | • Height — 86.8 mm (3.41 inches) • Width — 481.6 mm (18.96 inches) • Depth — 907.74mm (35.74 inches) |
| Chassis form factor | 2U rack server |
| System management | The following are the main features of the iDRAC service module: • iDRAC 9 • iDRAC Direct • iDRAC RESTful API with Redfish • iDRAC Service Module management software: • OpenManage Enterprise • OpenManage Power Manager plugin • OpenManage Service plugin • OpenManage Update Manager plugin • CloudIQ for PowerEdge plug in • OpenManage Enterprise Integration for VMware vCenter • OpenManage Integration for Microsoft System Center • OpenManage Center Integration with Windows Admin |
Warranty
Public manufacturer information does not specify the warranty term applicable to our supply channel. The supply region, channel and actual warranty service are confirmed in the supply contract.
Manufacturer information
Manufacturer informationVerified Documentation & Datasheets
Manufacturer product information
Download Document