Key Architecture Highlights
- Drive bays: Front bays: • Up to 6 x E3.S Gen5 NVMe, max 46.08 TB • Up to 6 x 2.5-inch NVMe, max 92.16 TB • Up to 8 x 2.5-inch SAS/SATA/NVMe, max 122.88 TB
- Cooling fans: • Standard (STD) fan • Up to six hot plug fans
- Chassis dimensions: • Height –86.8 mm (3.41 inches) • Width –482 mm (18.97 inches) • Depth –946.73 mm (37.27 inches) - without bezel 932.89 mm (36.73 inches) - with bezel
Applications
- AI training and inference
- High-performance computing
Engineering Parameters
| Supported processors | Up to two 4th Generation Intel Xeon Scalable processor with up to 56 cores per processor and optional Intel® QuickAssist Technology Up to two 5th Generation Intel Xeon Scalable processor with up to 64 cores per processor and optional Intel® QuickAssist Technology |
|---|---|
| Memory support | • 32 DDR5 DIMM slot, supports RDIMM 8 TB max • Speeds up to 4800 MT/s on the 4th Generation Intel® Xeon Scalable processor • Speeds up to 5600 MT/s on the 5th Generation Intel® Xeon Scalable processor • Supports registered ECC DDR5 DIMMs only |
| Storage controller | • Internal controllers: PERC H965i, PERC H755, PERC H755N, PERC H355, HBA355i, HBA465i • Internal Boot: Boot Optimized Storage Subsystem (BOSS-N1): HWRAID 2 x M.2 NVMe SSDs, or USB • External HBA (non-RAID): HBA355e, HBA465e, H965e • Software RAID: S160 |
| Drive bays | Front bays: • Up to 6 x E3.S Gen5 NVMe, max 46.08 TB • Up to 6 x 2.5-inch NVMe, max 92.16 TB • Up to 8 x 2.5-inch SAS/SATA/NVMe, max 122.88 TB |
| Power supply specifications | • 3200 W Titanium 277–305 VAC or 336 HVDC, hot swap redundant • 2800 W Titanium 200–240 VAC or 240 HVDC, hot swap redundant • 2400 W Platinum 100–240 VAC or 240 HVDC, hot swap redundant |
| Cooling fans | • Standard (STD) fan • Up to six hot plug fans |
| Chassis dimensions | • Height –86.8 mm (3.41 inches) • Width –482 mm (18.97 inches) • Depth –946.73 mm (37.27 inches) - without bezel 932.89 mm (36.73 inches) - with bezel |
| Chassis form factor | 2U rack server |
| System management | • iDRAC 9 • iDRAC Direct • iDRAC RESTful API with Redfish • iDRAC Service Module • Quick Sync 2 wireless module management software: • OpenManage Enterprise • OpenManage Power Manager plugin • OpenManage Service plugin • OpenManage Update Manager plugin management software: • CloudIQ for PowerEdge plug in • OpenManage Enterprise Integration for VMware vCenter • OpenManage Integration for Microsoft System Center • OpenManage Integration with Windows Admin Center |
| Security features | • Cryptographically signed firmware • Data at Rest Encryption (SEDs with local or external key mgmt) • Secure Boot • Secured Component Verification (Hardware integrity check) • Secure Erase • Silicon Root of Trust • System Lockdown (requires iDRAC9 Enterprise or Datacenter) • TPM 2.0 FIPS, CC-TCG certified, TPM 2.0 China NationZ |
Warranty
Public manufacturer information does not specify the warranty term applicable to our supply channel. The supply region, channel and actual warranty service are confirmed in the supply contract.
Manufacturer information
Manufacturer informationVerified Documentation & Datasheets
Manufacturer product information
Download Document